737 research outputs found

    Development of biobased building blocks, polymers and coatings

    Get PDF
    Coatings are omnipresent in daily life, indispensable in construction and applied everywhere around us to enhance the durability and aesthetics of numerous products ranging from cars to wood to electronics. One of the most conventional sets of building blocks used to build these polymer chains, justified by their high reactivity and broad versatility, are the petrochemical feedstock derived acrylates. Despite their promise, the high demand and the resulting large-scale production from fossil fuels contribute heavily to an unsustainable ecological footprint. As a result of the growing environmental awareness and the desire for a green future, sustainable production of acrylates and the development of acrylate alternatives derived from biorenewable resources have gained increased attention over the last decades. Although great progress has been made, the commercialization of a competing sustainable process has not yet been achieved due techno-economic challenges arising from the underdeveloped larger scale syntheses and expensive starting materials and reagents. In this thesis we implemented both strategies and present several new developments towards sustainable acrylate alternatives (alkoxybutenolides) and biobased acrylic acid, all starting from furfural and using oxygen and visible light for sustainable chemical transformations. In order to account for a larger scale synthesis, a photochemical reactor was developed for the continuous production of our sustainable building blocks. The resulting biobased coatings obtained from these alkoxybutenolides are hard, transparent and resistant to solvent and water, similar to commercial coatings. Above all, the coatings are functional and have tunable properties, based on the different building blocks we developed

    A model-based approach to stabilizing crutch supported paraplegic standing by artifical hip joint stiffness

    Get PDF
    The prerequisites for stable crutch supported standing were analyzed in this paper. For this purpose, a biomechanical model of crutch supported paraplegic stance was developed assuming the patient was standing with extended knees. When using crutches during stance, the crutches will put a position constraint on the shoulder, thus reducing the number of degrees of freedom. Additional hip-joint stiffness was applied to stabilize the hip joint and, therefore, to stabilize stance. The required hip-joint stiffness for changing crutch placement and hip-joint offset angle was studied under static and dynamic conditions. Modeling results indicate that, by using additional hip-joint stiffness, stable crutch supported paraplegic standing can be achieved, both under static as well as dynamic situations. The static equilibrium postures and the stability under perturbations were calculated to be dependent on crutch placement and stiffness applied. However, postures in which the hip joint was in extension (C postures) appeared to the most stable postures. Applying at least 60 N /spl middot/ m/rad hip-joint stiffness gave stable equilibrium postures in all cases. Choosing appropriate hip-joint offset angles, the static equilibrium postures changed to more erect postures, without causing instability or excessive arm forces to occur

    Changes in circle area after gravity compensation training in chronic stroke patients

    Get PDF
    After a stroke, many people experience difficulties to selectively activate muscles. As a result many patients move the affected arm in stereotypical patterns. Shoulder abduction is often accompanied by elbow flexion, reducing the ability to extend the elbow. This involuntary coupling reduces the patient's active range of motion. Gravity compensation reduces the activation level of shoulder abductors which limits the amount of coupled elbow flexion. As a result, stroke patients can instantaneously increase their active range of motion [1]. The objective of the present study is to examine whether training in a gravity compensated environment can also lead to an increased range of motion in an unsupported environment. Parts of this work have been presented at EMBC2009, Minneapolis, USA

    Medical Information Representation Framework for Mobile Healthcare

    Get PDF
    In mobile healthcare, medical information are often expressed in different formats due to the local policies and regulations and the heterogeneity of the applications, systems, and the adopted Information and communication technology. This chapter describes a framework which enables medical information, in particular clinical vital signs and professional annotations, be processed, exchanged, stored and managed modularly and flexibly in a mobile, distributed and heterogeneous environment despite the diversity of the formats used to represent the information. To deal with medical information represented in multiple formats the authors adopt techniques and constructs similar to the ones used on the Internet, in particular, the authors are inspired by the constructs used in multi-media e-mail and audio-visual data streaming standards. They additionally make a distinction of the syntax for data transfer and store from the syntax for expressing medical domain concepts. In this way, they separate the concerns of what to process, exchange and store from how the information can be encoded or transcoded for transfer over the internet. The authors use an object oriented information model to express the domain concepts and their relations while briefly illustrate how framework tools can be used to encode vital sign data for exchange and store in a distributed and heterogeneous environment

    The influence of the reciprocal cable linkage in the advanced reciprocating gait orthosis on paraplegic gait performance

    Get PDF
    A wide variety of mechanical orthoses is available to provide ambulation to paraplegic patients. Evaluation of energy cost during walking in each of these devices has been acknowledged as an important topic in this field of research. In order to investigate the benefits of a ballistic swing on gait performance in the Advanced Reciprocating Gait Orthosis (ARGO) a study was conducted in which the ARGO was compared with an orthosis with freely swinging legs. This Non Reciprocally linked Orthosis (NRO) was obtained by removing the reciprocal linkage in the subjects' own ARGOs. Subsequently, flexion/extension limits were mounted to permit adjustment of stride length. Six male paraplegic subjects with lesions ranging from T4 to T12 were included in the study. A single case experimental design (B-A-B-A) was conducted in order to improve internal validity. Biomechanical and physiological parameters were assessed and the subjects' preference for either ARGO or NRO was determined.\ud \ud It was found that large inter-individual differences produced insufficient evidence in this study to draw general conclusions about difference in energy expenditure between both orthoses. However, individual analysis of the results showed a reduction of oxygen cost (range: 4%-14%) in the NRO in T9 and T12 lesions, while oxygen cost in subjects with T4 lesions increased markedly (22% and 40%). It is concluded that patients with low level lesions could benefit in terms of oxygen lost from removing the reciprocal cable linkage in the ARGO. However, only one subject preferred the NRO for walking, whereas none of the subject chose the NRO for use in daily living activities. Removal of the reciprocal cable linkage in the ARGO may not be desirable for these patients

    A Feasibility Study in Measuring Soft Tissue Artifacts on the Upper Leg Using Inertial and Magnetic Sensors

    Get PDF
    Soft-tissue artifacts cause inaccurate estimates of body segment orientations. The inertial sensor (or optical marker) is orientating (or displacing) with respect to the bone it has to measure, due to muscle and skin movement [1]. In this pilot study 11 inertial and magnetic sensors (MTw, Xsens Technologies) were placed on the rectus femoris, vastus medialis and vastus lateralis (upper leg). One sensor was positioned on the tendon plate behind the quadriceps (iliotibial tract, as used in Xsens MVN [1]) and used as reference sensor. Walking, active and passive knee extensions and muscle contractions without flexion/extension were recorded using one subject. The orientation of each sensor with respect to the reference sensor was calculated. During walking, relative orientations of up to 28.6º were measured (22.4±3.6º). During muscle contractions without flexion/extension the largest relative orientations were measured on the rectus femoris (up to 11.1º) [2]. This pilot showed that the ambulatory measurement of deformation of the upper leg is feasible; however, improving the measurement technology is required. We therefore have designed a new inertial and magnetic sensor system containing smaller sensors, based on the design of an instrumented glove for the assessment of hand kinematics [3]. This new sensor system will then be used to investigate soft-tissue artifacts more accurately; in particular we will focus on in-use estimation and elimination of these artifacts

    The influence of frontal alignment in the advanced reciprocating gait orthosis on energy cost and crutch force requirements during paraplegic gait

    Get PDF
    Reduction of energy cost and upper body load during paraplegic walking is considered to be an important criterion in future developments of walking systems. A high energy cost limits the maximum walking distance in the current devices, whereas wrist and shoulder pathology can deteriorate because of the high upper body load. A change in alignment of the mechanical brace in the frontal plane, i.e. abduction, can contribute to a more efficient gait pattern with sufficient foot clearance with less pelvic lateral sway. A decrease in pelvic lateral sway after aligning in abduction results in a shift of the centre of mass to the swing leg crutch which may result in a decrease in required crutch force on stance side to maintain foot clearance. Five paraplegic subjects were provided with a standard Advanced Reciprocating Gait Orthosis (ARGO) and an ARGO aligned in 4 different degrees of abduction (0°, 3°, 6° and 9°). After determining an optimal abduction angle for each of the subjects, a cross over design was used to compare the ARGO with the individually optimised abducted orthosis. An abduction angle between 0° and 3° was chosen as optimal abduction angle. Subjects were not able to walk satisfactory with abduction angles 6° and 9°. A significant reduction in crutch peak force on stance side was found (approx. 12% , p < 0.01) in the abducted orthosis. Reduction in crutch force time integral (15%) as well as crutch peak force on swing side (5%) was not significant. No differences in oxygen uptake as well as oxygen cost was found. We concluded that an abduction angle between 0° and 3° is beneficial with respect to upper boHy load, whereas energy requirements did not change

    Speakable in Quantum Mechanics

    Get PDF
    At the 1927 Como conference Bohr spoke the now famous words "It is wrong to think that the task of physics is to find out how nature is. Physics concerns what we can say about nature." However, if the Copenhagen interpretation really holds on to this motto, why then is there this feeling of conflict when comparing it with realist interpretations? Surely what one can say about nature should in a certain sense be interpretation independent. In this paper I take Bohr's motto seriously and develop a quantum logic that avoids assuming any form of realism as much as possible. To illustrate the non-triviality of this motto a similar result is first derived for classical mechanics. It turns out that the logic for classical mechanics is a special case of the derived quantum logic. Finally, some hints are provided in how these logics are to be used in practical situations and I discuss how some realist interpretations relate to these logics
    corecore